1. FUNCTIONS AND CONFIGURATION

1.8 Configuration including peripheral equipment

CAUTION
(1) MR-JE-100A or less
The diagram shows MR-JE-40A.
(Note 1)
Power
supply
Molded-case
circuit breaker
(Note 2)
Magnetic
contactor
(MC)
Power factor
improving AC
reactor
(FR-HAL)
Line noise
filter
(FR-BSF01)
Note 1. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. For the power supply
specifications, refer to section 1.3.
2. Depending on the power supply voltage and operation pattern, bus voltage can decrease. This can shift the mode to the
dynamic brake deceleration during forced stop deceleration. When dynamic brake deceleration is not required, slow the time to
turn off the magnetic contactor.
Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the servo
amplifier may cause a malfunction.
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
R S T
L1
L2
L3
CN3
CN1
CN2
U
V
W