11. OPTIONS AND PERIPHERAL EQUIPMENT
(c) Cable clamp fitting AERSBAN-_SET
Generally, connecting the grounding of the shielded wire to the SD terminal of the connector
provides a sufficient effect. However, the effect can be increased when the shielded wire is
connected directly to the grounding plate as shown below.
Install the grounding plate near the servo amplifier for the encoder cable. Peel part of the cable
sheath to expose the external conductor, and press that part against the grounding plate with the
cable clamp. If the cable is thin, clamp several cables in a bunch.
The cable clamp comes as a set with the grounding plate.
Dimensions
Cable
Cable clamp
(A, B)
External conductor
Clamp section diagram
2-φ5 hole
installation hole
(Note) M4 screw
Note. Screw hole for grounding. Connect it to the grounding plate of the cabinet.
Model
A
AERSBAN-DSET
100
AERSBAN-ESET
70
Strip the cable sheath of
the clamped area.
Grounding plate
[Unit: mm]
Grounding plate
17.5
6
22
35
B
C
Accessory fittings
86
30
Clamp A: 2 pcs.
56
Clamp B: 1 pc.
11 - 25
[Unit: mm]
cutter
cable
[Unit: mm]
Clamp section diagram
L or less
10
Clamp fitting
L
A
70
B
45