Mitsubishi Electric MR-JE-_A Instruction Manual page 285

General-purpose ac servo amplifier
Hide thumbs Also See for MR-JE-_A:
Table of Contents

Advertisement

11. OPTIONS AND PERIPHERAL EQUIPMENT
(3) MR-RB50
Cooling fan mounting
screw (2-M3 screw)
On opposite side
49
82.5
2.3
200
217
(4) MR-RB032
φ6 mounting hole
30
15
TE1
6
Approx. 20
7 × 14
slotted hole
7
12
17
108
120
[Unit: mm]
5
1.6
99
119
[Unit: mm]
Intake
Approx. 30
8
TE1 terminal
G3
G4
P
C
Applicable wire size: 0.2 mm
12)
Tightening torque: 0.5 to 0.6 [N•m]
Mounting screw
Screw size: M5
Tightening torque: 3.24 [N•m]
Mass: 0.5 [kg]
11 - 12
Terminal block
P
C
G3
G4
Terminal screw size: M4
Tightening torque: 1.2 [N•m]
Mounting screw
Screw size: M6
Tightening torque: 5.4 [N•m]
Mass: 5.6 [kg]
2
to 2.5 mm
2
(AWG 24 to

Hide quick links: