Quality Control Settings - Leica GPS1200 Field Manual

System
Hide thumbs Also See for GPS1200:
Table of Contents

Advertisement

17.4

Quality Control Settings

Description
Access
CONFIGURE
Quality Control
Settings
Config...\Survey Settings...
The settings on this screen define the limits for coordinate quality and DOP values
accepted for point occupations.
Select Main Menu: Config...\Survey Settings...\Quality Control Settings.
Description of fields
Field
Option
<CQ
None, Pos Only,
Control:>
Height Only or
Pos & Height
<Maximum
User input
CQ:>
<DOP Limit:> None, GDOP,
PDOP, HDOP or
VDOP
<Maximum
User input
DOP:>
<Allow 2D
Yes
Posn:>
No
Next step
CONT (F1) returns to the screen from where CONFIGURE Quality Control
Settings was accessed.
Description
The type of coordinate quality to be checked
before storing a point. If activated, the limit
defined in <Maximum CQ:> is checked before
storing a point.
Available unless <CQ Control: None>.
The maximum acceptable coordinate quality.
If activated, the limit defined in <Maximum
DOP:> is checked. GPS positions are unavail-
able when the limit is exceeded.
Available unless <DOP Limit: None>.
The maximum acceptable DOP value.
2D positions can be obtained with only three
satellites available. The height is fixed to that of
the last position computed with height.
2D positions cannot be obtained with only three
satellites available.