2.5 Adjusting the Paper Near-end Sensor
Below are two situations where a paper near-end sensor adjustment is required.
•
To adjust the detection position to suit the diameter of the roll paper core used.
•
To adjust the detection position of remaining amount of paper.
CAUTION!
Since roll paper cores vary slightly in shape, depending on paper roll design and
manufacturing tolerances, it is impossible to detect the remaining paper exactly.
Follow the steps below to adjust the roll paper near-end detector.
1.
Open the roll paper cover, and remove the roll paper.
2.
You will see a black lever inside as shown below.
3.
Adjust the lever according to your need.
Adjustments position
1 (Minimum)
2
3
4
5
6 (Maximum)
Remaining amount of paper (outer diameter: mm)
Approx. 26 {1.02"}
Approx. 27 {1.06"}
Approx. 28 {1.10"}
Approx. 30 {1.18"}
Approx. 32 {1.26"}
Approx. 33 {1.30"}