YASKAWA SI-P3 Installation Manual page 36

Profibus-dp
Hide thumbs Also See for SI-P3:
Table of Contents

Advertisement

6 Related Parameters
No.
(Addr. Hex)
F7-64
(784)
PZD5 Write
<4> <8>
F7-65
(785)
PZD6 Write
<4> <8>
F7-66
(786)
PZD7 Write
<4> <8>
F7-67
(787)
PZD8 Write
<4> <8>
F7-68
(788)
PZD9 Write
<4> <8>
F7-69
(789)
PZD10 Write
<4> <8>
F7-70
(78A)
PZD1 Read
<4> <8>
F7-71
PZD2 Read
(78B)
<4> <8>
F7-72
(78C)
PZD3 Read
<4> <8>
F7-73
(78D)
PZD4 Read
<4> <8>
F7-74
(78E)
PZD5 Read
<4> <8>
F7-75
(78F)
PZD6 Read
<4> <8>
F7-76
(790)
PZD7 Read
<4> <8>
F7-77
(791)
PZD8 Read
<4> <8>
36
Name
Sets MEMOBUS/Modbus address for PZD5 Write
(PPO Write).
The value of 0 to 2 disables the PZD5 Write.
Sets MEMOBUS/Modbus address for PZD6 Write
(PPO Write).
The value of 0 to 2 disables the PZD6 Write.
Sets MEMOBUS/Modbus address for PZD7 Write
(PPO Write).
The value of 0 to 2 disables the PZD7 Write.
Sets MEMOBUS/Modbus address for PZD8 Write
(PPO Write).
The value of 0 to 2 disables the PZD8 Write.
Sets MEMOBUS/Modbus address for PZD9 Write
(PPO Write).
The value of 0 to 2 disables the PZD9 Write.
Sets MEMOBUS/Modbus address for PZD10 Write
(PPO Write).
The value of 0 to 2 disables the PZD10 Write.
Sets MEMOBUS/Modbus address for PZD1 Read
(PPO Read).
The value of 0 to 2 enables the PZD1 Read as ZSW.
Sets MEMOBUS/Modbus address for PZD2 Read
(PPO Read).
The value of 0 to 2 enables the PZD2 Read as HIW.
Sets MEMOBUS/Modbus address for PZD3 Read
(PPO Read).
The value of 0 to 2 disables the PZD3 Read.
Sets MEMOBUS/Modbus address for PZD4 Read
(PPO Read).
The value of 0 to 2 disables the PZD4 Read.
Sets MEMOBUS/Modbus address for PZD5 Read
(PPO Read).
The value of 0 to 2 disables the PZD5 Read.
Sets MEMOBUS/Modbus address for PZD6 Read
(PPO Read).
The value of 0 to 2 disables the PZD6 Read.
Sets MEMOBUS/Modbus address for PZD7 Read
(PPO Read).
The value of 0 to 2 disables the PZD7 Read.
Sets MEMOBUS/Modbus address for PZD8 Read
(PPO Read).
The value of 0 to 2 disables the PZD8 Read.
YASKAWA ELECTRIC TOBP C730600 82B YASKAWA AC Drive Option SI-P3 Installation Manual
Description
Values
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH

Advertisement

Table of Contents
loading

Table of Contents