3.4
Technical specifications
3.4.1
General technical data
General information
Measured components
Measuring ranges
Characteristics
Operator panel
Operating position
Shocks / maximum vibration
Software release of TÜV version (7MB235x)
Enclosure
Weight
Degree of protection
ULTRAMAT 23
Manual, 3/2016, A5E37100388-003
Maximum of 4, comprising up to three infrared-sensitive gases as well as
oxygen and/or hydrogen sulfide (H
sensitive gases)
2 per component
Linearized
LCD with LED backlighting and contrast control, 80 characters (4 lines à
20 characters); function keys
Front panel vertical
No shocks; maximum vibration 5 m/s
3.00.07
Approx. 10 kg (22 lbs.) The weight varies according to the ordered vari-
ant.
IP40 in accordance with EN 60529 for the versions 7MB235x (TÜV)
IP20 in accordance with EN 60529 for the versions 7MB233x (standard)
3.4 Technical specifications
S is not available with 3 infrared-
2
2
Description
31