The table below lists the Programming Console operations, a brief description, and the page on which they
appear in the body of this manual. All operations are described briefly, and the key sequence for inputting
them given, in the tables which form the second part of this appendix.
Name
Password Input
Buzzer ON/OFF
Data Clear
I/O Table Register
I/O Table Verify
I/O Table Read
NET Link Table Transfer
I/O Table Delete
Address Designation
Program Input
Program Read
Program Search
Instruction Insert
Instruction Delete
Program Check
Error Message Read
Bit/Word Monitor
3-word Monitor
Forced Set/Reset
Clear Forced Set/Reset
Hex/BCD Data Change
Binary Data Change
SV Change/SV Reset
3-word Change
Cycle Time Display
Hex–ASCII Display Change
Binary Monitor
Program Memory Save
Program Memory Restore
Program Memory Compare
DM Data Save, Restore,
Compare
Appendix C
Programming Console Operations
Prompts the user for the access password.
Controls whether the buzzer will sound for keystroke inputs.
Used to erase data, either selectively or totally, from the Program Memory and the
IR, AR, HR, DM, and TC areas.
Registers the I/O table after initial entry or subsequent amendments.
Checks the I/O Table against the actual arrangement of I/O Units.
Displays the Unit type, location, allocated I/O word, and word multiplier (where applica-
ble).
Transfers a copy of the NET Link System's Link Table to the user memory (UM) area. 70
Deletes the entire I/O Table.
Displays the specified address.
Used to edit or input program instructions.
Allows the user to scroll through the program address-by-address. In RUN and
MONITOR modes, status of bits is also given.
Searches a program for the specified data address or instruction.
Allows a new instruction to be inserted before the displayed instruction, or deletes
the displayed instruction (respectively).
Checks the completed program for syntax errors (up to three levels in H-type PCs).
Displays error messages in sequence, starting with the most severe messages.
Displays the specified address whose operand is to be monitored. In RUN or MONTR
mode it will show the status of the operand for any bit or word in any data area.
Simultaneously monitors three consecutive words.
Set: Used to turn ON bits or timers, or to increment counters currently displayed on
the left of the screen.
Reset: Used to turn OFF bits, or to reset timers or counters.
Simultaneously clears all forced bits within the currently displayed word.
Used to change the value of the leftmost BCD or hexadecimal word displayed dur-
ing a Bit/Word Monitor operation.
Changes the value of 16-bit words bit-by-bit. Bits can be changed temporarily or
permanently to the desired status.
Alters the SV of a timer or counter either by incrementing or decrementing the val-
ue, or by overwriting the original value with a new one.
Used to change the value of a word displayed during a 3-word Monitor operation.
Measures the duration of the current cycle. Cycle times will vary according to the
execution conditions which exist in each cycle.
Converts 4-digit hexadecimal data in the DM area to ASCII and vice-versa.
Displays the monitored area in binary format.
Saves Program Memory to tape.
Reads Program Memory from tape.
Compares Program Memory data on tape with that in the Program Memory area.
The save, restore, and compare tape operations for DM area data.
Function
Reference page
62
63
63
65
66
67
69
72
73
72
79
73
76
264
238
246
241
243
244
249
251
247
78
245
248
254
256
256
258
315