Reversible Shift Register - Sftr(84) - Omron C200H Operation Manual

Hide thumbs Also See for C200H:
Table of Contents

Advertisement

Data Shifting
00001
00000
00003
HR 0003
00002
5-13-2
REVERSIBLE SHIFT REGISTER – SFTR(84)
Limitations
Description
used to detect faulty products in the shoot so that the pusher output and HR
0003 of the shift register can be reset as required.
Sensor
(00001)
Rotary Encoder
(00000)
I
SFT(10)
P
HR 00
R
HR 01
00500
HR 0003
Ladder Symbols
SFTR(84)
@SFTR(84)
C
St
E
St and E must be in the same data area and St must be less than or equal
to E.
SFTR(84) is used to create a single- or multiple-word shift register that can
shift data to either the right or the left. To create a single-word register, desig-
nate the same word for St and E. The control word provides the shift direc-
Pusher
(00500)
Sensor
(00002)
Chute
Address Instruction
00000
LD
00001
LD
00002
LD
00003
SFT(10)
00004
LD
00500
00005
OUT
00006
LD
00007
OUT NOT
00008
OUT NOT
C
St
E
Section 5-13
Operands
00001
00000
00003
HR
00
HR
01
HR
0003
00500
00002
00500
HR
0003
Operand Data Areas
C: Control word
IR, AR, DM, HR, LR
St: Starting word
IR, AR, DM, HR, LR
E: End word
IR, AR, DM, HR LR
125

Advertisement

Table of Contents
loading

Table of Contents