AR Area
1, 2, 3... 1.
3-5-7

TERMINAL Mode Key Bits (CPU11-E Only)

3-5-8

Power-OFF Counter

36
Turn ON AR 2114 (Stop Bit).
2.
Set the desired date, day, and time, being careful not to turn OFF AR
2114 (Stop Bit) when setting the day of the week (they're in the same
word). (On the Programming Console, the Bit/Digit Monitor and Force
Set/Reset Operations are the easiest ways to set this data.)
Note A more convenient way is if steps 1 and 2 are executed simulta-
neously as follows.
Set 4000 to 4006 with present value change.
Stop bit ON data
3.
Turn ON AR 2115 (Reset Bit). The Calendar/clock will automatically start
operating with the designated settings and AR 2114 and AR 2115 will
both be turned OFF.
The Calendar/clock Area and Bits are refreshed each cycle while operational.
If the Programming Console is mounted to the PC and is in TERMINAL
mode, any inputs on keys 0 through 9 (including characters A through F, i.e,
keys 0 through 5 with SHIFT) will turn on a corresponding bit in AR 22. TER-
MINAL mode is entered either through Programming Console operations or
by executing KEY(62).
The bits in AR 22 correspond to Programming Console inputs as follows:
Bit
Programming Console input
AR 2200
0
AR 2201
1
AR 2202
2
AR 2203
3
AR 2204
4
AR 2205
5
AR 2206
6
AR 2207
7
AR 2208
8
AR 2209
9
AR 2210
A
AR 2211
B
AR 2212
C
AR 2213
D
AR 2214
E
AR 2215
F
Refer to Section 5 Instruction Set for details on KEY(62) and to Section 7
Program Monitoring and Execution for details on the TERMINAL mode.
AR 23 provides in 4-digit BCD the number of times that the PC power has
been turned off. This counter can be reset as necessary using the PV
Change 1 operation from the Programming Console. (Refer to 7-1-4 Hex/
BCD Data Modification for details.) The Power-OFF Counter is refreshed
every time power is turned on.
Section 3-5