Terms - Mitsubishi Electric MELSEC iQ-R Series Configuration Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

TERMS

Unless otherwise specified, this manual uses the following terms.
Term
Base unit
C Controller module
CC-Link IE
CC-Link IE Controller Network-equipped module
CC-Link IE Field Network-equipped master/local module
Control CPU
Control system
CPU module
Dedicated instruction
Engineering tool
Ethernet interface module with built-in CC-Link IE
Extended temperature range base unit
Extension base unit
Extension cable
I/O module
Intelligent function module
Main base unit
Motion CPU
Multiple CPU system
NCCPU
Network module
New control system
Power supply module
Process CPU
Process CPU (process mode)
Process CPU (redundant mode)
Programmable controller CPU
Q5B
Q6B
Redundant function module
Redundant power supply base unit
22
Description
A generic term for main base units, extension base units, and RQ extension base units
A generic term for the MELSEC iQ-R series C Controller module
A generic term for CC-Link IE Controller Network and CC-Link IE Field Network
A generic term for the following modules when the CC-Link IE Controller Network function is used:
• RJ71GP21-SX
• RJ71EN71
• RnENCPU
A generic term for the following modules when the CC-Link IE Field Network function is used:
• RJ71GF11-T2
• RJ71EN71
• RnENCPU
A CPU module that controls connected I/O modules and intelligent function modules.
In a multiple CPU system, a control CPU is set to each connected module.
A system that controls a redundant system and performs network communications in a redundant
system
A generic term for the MELSEC iQ-R series CPU modules
An instruction that facilitates the programming to use the functions of a module
The product name of the software package for the MELSEC programmable controllers
Another name for the RJ71EN71
A generic term for base units compatible with an operating ambient temperature of 0 to 60.
The abbreviation for the MELSEC iQ-R series extension base unit
The abbreviation for the MELSEC iQ-R series extension cable
A generic term for the input module, output module, I/O combined module, and interrupt module
A module that has functions other than input and output, such as an A/D converter module and D/
A converter module
The abbreviation for the MELSEC iQ-R series main base unit
A generic term for MELSEC iQ-R series Motion controllers
A system where 2 to 4 CPU modules control I/O modules or intelligent function modules assigned
to
Another term for the R16NCCPU
A generic term for the following modules:
• Ethernet interface module
• CC-Link IE Controller Network module
• Module on CC-Link IE Field Network
• MELSECNET/H network module
• MELSECNET/10 network module
• RnENCPU (network part)
A system that has switched to control system from standby system after system switching
The abbreviation for the MELSEC iQ-R series power supply module
A generic term for the R08PCPU, R16PCPU, R32PCPU, and R120PCPU
A Process CPU that operates in the process mode.
Process control function block and the online module change function can be executed.
A Process CPU that operates in the redundant mode.
This CPU module can be used for building a redundant system. Process control function block
and the online module change function can be executed even in this mode.
A generic term for the R04CPU, R04ENCPU, R08CPU, R08ENCPU, R16CPU, R16ENCPU,
R32CPU, R32ENCPU, R120CPU, and R120ENCPU
The abbreviation for the MELSEC-Q series extension base unit (type requiring no power supply
module)
The abbreviation for the MELSEC-Q series extension base unit (type requiring a power supply
module)
Another term for the R6RFM.
This module is used with a Process CPU (redundant mode) as a pair, to build a redundant system.
A generic term for base units used for a redundant configuration of power supplies.
This unit is used together with redundant power supply modules, to build a redundant power
supply system.

Advertisement

Table of Contents
loading

Table of Contents