Positioning module
• Set parameters in a program because positioning data cannot be written to the module. The positioning data parameter is
discarded when the GX Works2 project is read out.
• Check the latest error code with the system monitor because error codes for the QD70P4, QD70P8, QD70D4, and
QD70D8 cannot be checked in the module diagnostics. When multiple errors occur, refer to the buffer memory (error codes
for each axis) and check the error.
Loop control module
Check the latest error code with the system monitor because error codes for the Q62HLC cannot be checked in the module
diagnostics. When multiple errors occur, refer to the buffer memory and check the error.
FL-net(OPCN-2) interface module
• Select "Online" in "Operation Mode Setting" of "Switch Setting".
• Set parameters in a program because the auto refresh used in GX Works2 cannot be set in GX Works3.
• In GX Works2, the size of region 1 of cyclic data is set in units of bits, while in GX Works3, it is set in units of words.
MODBUS interface module and MODBUS/TCP interface module
• When "Start MODBUS device number" of "MODBUS device assignment parameter" is set, check the setting range in the
manual in advance.
• For "Basic parameter starting method" and "Device assignment parameter starting method" of "Switch setting" in "Basic
setting", only "Start by user setting parameter" can be selected. Write a program to set the automatic communication
parameters as well as module parameters set only "Switch setting" when the default assignment parameter is used as the
staring method.
• GX Works3 does not support the intelligent function module parameter "Setting for GX Works2 Connection" of GX Works2.
• Accessing via MODBUS using GX Works3 is not allowed.
• The Z(P).MBRW and Z(P).MBREQ instructions cannot be used. Instead of these instructions, use the automatic
communication function.
• Set parameters in a program because the auto refresh used in GX Works2 cannot be set in GX Works3.
AnyWireASLINK master module and AnyWire DB A20 master module
• Set a slave module by using the address writer because GX Works3 does not support "AnyWireASLINK Configuration" of
GX Works2.
• The auto-generation of a global label (CSV file output from the device assignment window) cannot be use.
• When the AnyWire DB A20 master module is used, select the following model displayed on "Module Configuration". The
model is also displayed on the diagnostic window.
Model
QJ51AW12D2
MES interface module and Web server module
Use the modules corresponding to the MELSEC iQ-R series. For the modules, refer to the following.
 MES Interface Module User's Manual
 Web Server Module User's Manual
Model displayed on GX Works3
MELSEC_Partner
Appendix 5 How to Use MELSEC-Q Series Modules