The following table shows the specifications of the FCN-363T-T005/H used for the A6CON2.
Applicable wire size
Cross-section area of
wire
AWG24
0.20 to 0.24
AWG26
0.13 to 0.16
AWG28
0.088 to 0.096
Wiring of the A6CON2 requires the special tool.
For how to use and adjust the tool, contact the manufacturer.
Arrangement for a flat cable is in the order of A1  B1  A2 
(The following figure shows a connector viewed from the plug-in side.)
B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B09 B08 B07 B06 B05 B04 B03 B02 B01
A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A09 A08 A07 A06 A05 A04 A03 A02 A01
4.
Place the connector on one side of the connector cover
and put the fixing screws through the screw holes.
Cover another connector cover onto the connector.
5.
Tighten the four screws.
Crimp height
Sheath outside
diameter of wire
1.2 or less
1.25 to 1.30
1.2 or less
1.20 to 1.25
1.2 or less
1.15 to 1.20
Length of stripped wire
part
3.0 to 4.0
3.0 to 4.0
3.0 to 4.0