Axis Series – RX User Guide
Software v2.0 and above
Screenshot: Frequency Tab
Step 2: Configure the Scan Settings Pane
1. Click the Refresh button – this resets any previous scans in the frequency scanner.
2. Type in the Start frequency in MHz you want to use for your Frequency scan. If you
enter a frequency that is too low the Start frequency will set itself to the lowest
frequency this AXRX1 can perform.
3. Type in the End frequency in MHz you want to use for your Frequency scan. If you enter
a frequency that is too high the End frequency will set itself to the highest frequency this
AXRX1 can perform.
Note: The wider the band you want to scan using the Start and Stop setting, the longer the
scan will take.
4. Type in the Resolution frequency in MHz you want to use for your Frequency scan. If
you enter a very small resolution like 0.5 MHz the scan will find many more discrete
frequencies but the scan will take longer. Using a larger resolution will speed up the scan
but may miss very fine frequency steps.
5. Click the Apply button.
6. The Scan Settings message window opens.
7. Click the OK button.
Revision 2.5
February 2015
Figure 6-35 Frequency Tab