Temperature Monitoring; Overcharging Protection - Fronius ActiveCharger 1000 Operating Instructions & Parts List Manual

Hide thumbs Also See for ActiveCharger 1000:
Table of Contents

Advertisement

Temperature
Temperature monitoring prevents the battery from being charged or discharged if the
monitoring
temperature of the battery is outside the permitted temperature range.
Undertemperature:
If the battery falls below the permitted temperature range, neither welding nor charging is
possible.
If the battery is charged, it can be heated until welding is possible. To do this, proceed as
follows:
Charging is only possible again at a temperature of -10 °C.
Overtemperature:
If the battery exceeds the permitted temperature range:
-
-
Overcharging
Once the battery has been fully charged, the charger turns off automatically and switches
protection
to conservation charging mode.
In this mode the power source can remain connected to the charger for any length of time.
More information on how the charger and the individual operating modes work can be
found in the charger description on page 59.
32
Attempt to start welding
1
-
if the battery is still too cold, welding is not possible
-
the temperature indicator lights up and „cold" appears on the display
-
both indicators go out after approx. five seconds
Attempt to start welding again after approx. five seconds
2
-
if the battery is still too cold, welding is not possible
-
the temperature indicator lights up and „cold" appears on the display
-
both indicators go out after approx. five seconds
Repeat the procedure until the battery reaches the required operating temperature
3
(through multiple attempts to start welding)
the temperature indicator lights up and „hot" is shown on the display
neither welding nor charging is possible until the temperature indicator goes out
(when the battery has cooled down)