No function

The power source cannot be switched on
Cause:
Remedy:
Cause:
Remedy:
Battery is not charged
Power source is connected to the charger, charger is connected to the mains, no charging
indicator on the power source
Cause:
Remedy:
Cause:
Remedy:
No welding current
Power source is switched on, indicator for the selected welding process is lit
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
No welding current
Power source is switched on, indicator for the selected welding process is lit, overtemper-
ature indicator lit
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
The battery has entered a state of deep discharge as it has been stored for
too long without being charged
Charge the battery now
Battery operation is possible again above 25% capacity.
If charging is no longer possible, contact After-Sales Service.
Control panel defective
Contact After-Sales Service
Device is too hot
Check/reduce ambient temperature, allow battery to cool down
Device temperature too low
Check/increase ambient temperature
Welding power-lead connections have been disconnected
Establish proper welding power-lead connections
Poor or no earth
Establish a connection to the workpiece
There is a break in the power cable in the welding torch or electrode holder
Replace welding torch or electrode holder
Duty cycle exceeded - power source overloaded - fan running
Keep within duty cycle
Thermostatic automatic circuit breaker has been tripped
Wait until the power source comes back on automatically at the end of the
cooling phase
The fan in the power source is faulty
Contact After-Sales Service
Insufficient cooling air intake
Ensure adequate air supply
Air filter is dirty
Clean air filter