Service Messages - Fronius ActiveCharger 1000 Operating Instructions & Parts List Manual

Hide thumbs Also See for ActiveCharger 1000:
Table of Contents

Advertisement

Service messag-
When E and a 2 digit error number appear in the display (e.g. E02) and the "Error" indicator
es
lights up, this is an internal power source service code.
Example:
Make a note of the error numbers shown in the display, and of the serial number and con-
figuration of the power source, and contact our after-sales service team with a detailed de-
scription of the error.
E02 / E03 / E05 / E06
Cause:
Remedy:
E07
Cause:
Remedy:
E09 / E10
Cause:
Remedy:
E11
Cause:
Remedy:
E12 / E13 /E14
Cause:
Remedy:
E16
Cause:
Remedy:
E18
Cause:
Remedy:
E19 / E22
Cause:
Remedy:
E23
Cause:
Remedy:
52
It is also possible that several error numbers are present. These appear when turning
the adjusting dial.
Internal temperature sensor fault on ACCUPLT / ACCUPLT-TIG PC board
Contact after-sales service
15 V supply voltage too low
Contact after-sales service
Load too high on power source current sockets
Use power source correctly (welding)
No communication with the control panel
Contact after-sales service
Internal error on ACCUPLT / ACCUPLT-TIG PC board
Contact after-sales service
Communication error between battery and ACCUPLT / ACCUPLT-TIG PC
board
Contact after-sales service
Wrong firmware (software) has been loaded
Contact after-sales service
Battery fault
Contact after-sales service
A voltage of > 113 V DC has been measured on the current sockets
Contact After-Sales Service

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Accupocket 150/400

Table of Contents