Parameter
Parameters for
Parameter
TIG welding
46
Description
Break voltage (U cut off)
Used to specify at which arc length the welding
process is to be completed.
The welding voltage increases as the length of the
arc increases. The arc is extinguished when it
reaches the voltage specified here.
Factory setting: 45 volts
Software version
The full version number of the currently installed
software is spread across a number of displays
and can be retrieved by turning the adjusting dial.
Automatic switch-off (time Shut down)
If the power source is not operated for the speci-
fied length of time, it switches off automatically.
Factory setting: 900 seconds
Factory setting (FACtory)
The power source can be reset to its factory set-
tings here.
-
Cancel reset
-
Reset the parameters for the selected weld-
ing process to their factory settings
-
Reset the parameters for all welding process-
es to their factory settings
Resetting of the selected value to its factory set-
ting must be confirmed by pressing the adjusting
dial.
Description
Comfort Stop Sensitivity
Factory setting: 0.5
For details see the
TIG Comfort Stop
page
43
Break voltage (U cut off)
Used to specify at which arc length the welding
process is to be completed.
The welding voltage increases as the length of the
arc increases. The arc is extinguished when it
reaches the voltage specified here.
This parameter is only available when the CSS
parameter is set to OFF.
Factory setting: 15 volts
Range
Unit
25 - 80 Volts
300 - 900
Seconds
OFF
no
YES
ALL
Range
Unit
0.3 - 2.0
Volts
OFF
section on
12 - 35 Volts