Temperature Monitoring; Overcharging Protection - Fronius AccuPocket 150/400 TIG Operating Instructions Manual

Hide thumbs Also See for AccuPocket 150/400 TIG:
Table of Contents

Advertisement

Temperature
Temperature monitoring prevents the battery from being charged or discharged
monitoring
if the temperature of the battery is outside the permitted temperature range.
The battery charger has an internal temperature management function
-
-
-
-
-
Undertemperature
If the battery falls below the permitted temperature range, neither welding nor
charging is possible.
Overtemperature
Charging is only possible again at a battery temperature of less than +45 °C.
If the battery exceeds the permitted temperature range:
-
-
Overcharging
Once the battery has been fully charged, the charger turns off automatically and
protection
switches to conservation charging mode.
More information on how the battery charger and the individual operating modes
work can be found in the charger description on page 69.
32
From 30 °C: Protection against overheating of the charger by automatic re-
duction of the power (derating)
From 45 °C: Only standard charging possible to increase battery life
From 70 °C: Power source switched off
Charging is not possible below 0 °C. Welding is conditionally possible de-
pending on the current level.
Two additional sensors directly on the power module
the temperature indicator lights up and „hot" is shown on the display
neither welding nor charging is possible until the temperature indicator goes
out (when the battery has cooled down)