Binder 723
6
1
5
7
2
3
4
Top view
T10F
7.3

Option 2, code KF1

The stator housing has a 7‐pin (Binder 723) device
connector, to which you link the connection cable for
voltage supply and torque signal.
Conn.
Binder
Pin
1
Supply voltage zero
2
No function
3
Pre‐amplifier supply voltage
(+15 V)
4
Torque measurement signal
(12 V
PP
5
No function
6
Rotor excitation voltage
(54 V/80 V
7
Rotor excitation voltage (0 V)
Shielding connected to
housing ground
7.3.1

Adaptation to the cable length

The transmission method between the rotor and the
stator determines the function of the torque flange, which
is dependent on:
S the installation situation (for example, covering, area
free of metal parts)
S the length of the cable
S the tolerances of the excitation voltage supply
A0608-14.0 HBM: public
Assignment
; 5...15 kHz)
; approx.15 kHz)
PP
Electrical connection
Wire
MS3106
color
conn.
wh
bk
bu
rd
gn
gy
Pin
A
B
C
D
F
G
41