Manual Pulse Generator Testing (Optional) - ICP DAS USA i8094A Getting Started

Table of Contents

Advertisement

3.5 Manual Pulse Generator Testing (Optional)

The user could perform pulse generator function manually to drive forward or backward motion.
This operation could ensure if the DI signals are functioning normally and if the direction(+/-) is
correct, therefore the users could make further adjustments for lines and parameters.
The following gives you further information on three ways to initiate Manual Pulse Generator
Testing:
1. A/B phase Manual Pulse Generator:
Use the A/B phase Manual Pulse Generator for forward/backward moving.
(Please refer to Manual "i8094H_Manual_1.3tc.pdf" section 2.18.1, function i
i8094H_EXD_MP()for detail settings.)
2. Fixed-pulse driving Manual Pulse Generator: The users could preset the driving
pulses at a fixed intensity and when press the forward or backward button, the motor
will move a few steps(Pulse) forward or backward.
(Please refer to Manual "i8094H_Manual_1.3tc.pdf" section 2.18.2, function
i i2.18.2" i8094H_EXD_FP() for detail settings.)
Continuous- pulse driving Manual Pulse Generator:
3.
output-pulse frequency at a fixed velocity (Hz)
backward at
fixed velocity when pressing
will be stopped immediately when releasing the button.
(Please refer to Manual "i8094H_Manual_1.3tc.pdf" section 2.18.3, function
i8094H_EXD_CP() for detail settings.)
http://www.icpdas.com
The users could preset the
, the motor will keep on moving forward or
the forward or backward button and the motion
I8094A &I8094HGetting Started manual
Ver 1.3-- 38

Advertisement

Table of Contents
loading

This manual is also suitable for:

I-8094h