3.4 Motion Basic Configuration
Motion basic configuration that required for general purposes are as follow:
1. Pulse output mode setting: Pulse/Dir、CW/CCW...
i8094MF_SET_PULSE_MODE() (Please refer to Manual "i8094H_Manual_1.3tc.pdf"
section 2.4, function i8094H_SET_PULSE_MODE() for detail settings.)
2. Set up Max. speed limitation for each axis
(Please refer to Manual "i8094H_Manual_1.3tc.pdf" section 2.5, function
i8094H_SET_MAX_V () for detail settings.)
3. Encoder input setting (optional)
(Please refer to Manual "i8094H_Manual_1.3tc.pdf" section 2.11, function
i8094H_SET_ENCODER() for detail settings.)
4. DI noise filter setting( optional)
(Please refer to Manual "i8094H_Manual_1.3tc.pdf" section 2.15, function
i8094H_SET_FILTER() for detail settings.)
5. Circular motion declaration( Ring counter)( optional)
(Please refer to Manual "i8094H_Manual_1.3tc.pdf" section 2.16, function
i8094H_VRING_ENABLE() for detail settings.)