2 PRODUCT DESCRIPTION
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
2
Breaker arcing current (I
t)
Breaker control
Breaker flashover
Contact inputs (up to 96)
Contact outputs (up to 64)
Control pushbuttons
CyberSentry™ security
Data logger
Digital counters (8)
Digital elements (48)
Direct inputs and outputs (32)
Disconnect switches (16)
DNP 3.0 or IEC 60870-5-104 Comms
Event recorder
Fault detector and fault report
a) OVERVIEW
The D60 is available as a 19-inch rack horizontal mount or reduced-size (¾) vertical unit and consists of the following mod-
ules: power supply, CPU, CT/VT, digital input and output, transducer input and output, and inter-relay communications.
Each of these modules can be supplied in a number of configurations specified at the time of ordering. The information
required to completely specify the relay is provided in the following tables (see chapter 3 for full details of relay modules).
Order codes are subject to change without notice. See the GE Multilin ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
NOTE
The order code structure is dependent on the mounting option (horizontal or vertical) and the type of CT/VT modules (regu-
lar CT/VT modules or the HardFiber
b) ORDER CODES WITH TRADITIONAL CTS AND VTS
The order codes for the horizontal mount units with traditional CTs and VTs are shown below.
Table 2–3: D60 ORDER CODES FOR HORIZONTAL UNITS (SHEET 1 OF 2)
D60
-
*
**
- *
*
* - F
BASE UNIT
D60
|
|
|
|
|
CPU
T
|
|
|
|
SOFTWARE
00
|
|
|
02
|
|
|
03
|
|
|
05
|
|
|
06
|
|
|
07
|
|
|
08
|
|
|
09
|
|
|
(CyberSentry Lvl 1)
A0
|
|
|
A2
|
|
|
A3
|
|
|
A5
|
|
|
A6
|
|
|
A7
|
|
|
A8
|
|
|
A9
|
|
|
(IEEE 1588)
B0
|
|
|
B2
|
|
|
B3
|
|
|
B5
|
|
|
B6
|
|
|
B7
|
|
|
B8
|
|
|
B9
|
|
|
(IEEE1588+Cyber Sentry Lvl 1)
D0
|
|
|
D2
|
|
|
D3
|
|
|
D5
|
|
|
D6
|
|
|
D7
|
|
|
D8
|
|
|
D9
|
|
|
GE Multilin
FUNCTION
Fault locator
FlexElements™ (8)
FlexLogic equations
IEC 61850 communications (optional)
Line pickup
Load encroachment
Metering: current, energy, frequency,
power, power factor, voltage
Modbus user map
Non-volatile latches
Non-volatile selector switch
Open pole detector
Oscillography
Pilot schemes
Setting groups (6)
Synchrophasors
for the latest ordering options.
TM
modules). The order code options are described in the following sub-sections.
**
- H
**
- M
**
- P
**
- U
**
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D60 Line Distance Protection System
FUNCTION
Time synchronization over IRIG-B or
IEEE 1588
Time synchronization over SNTP
Transducer inputs and outputs
Trip bus
User-definable displays
User-programmable LEDs
User-programmable pushbuttons
User-programmable self-tests
Virtual inputs (64)
Virtual outputs (96)
VT fuse failure
- W/X
**
Full Size Horizontal Mount
|
Base Unit
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
|
No software options
|
Breaker-and-a-half software
|
IEC 61850 communications
|
Breaker-and-a-half software and IEC 61850 communications
|
Phasor measurement unit (PMU)
|
IEC 61850 communications and phasor measurement unit (PMU)
|
Breaker-and-a-Half and phasor measurement unit (PMU)
|
Breaker-and-a-Half, IEC 61850 communications, and phasor measurement unit (PMU)
|
CyberSentry Lvl 1
|
CyberSentry Lvl 1 and Breaker-and-a-half
|
CyberSentry Lvl 1 and IEC 61850
|
CyberSentry Lvl 1 and IEC 61850 and Breaker-and-a-half
|
CyberSentry Lvl 1 and phasor measurement unit (PMU)
|
CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
|
CyberSentry Lvl 1 and phasor measurement unit (PMU) and Breaker-and-a-half
|
CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU) and Breaker-and-a-half
|
IEEE 1588
|
IEEE 1588 and Breaker-and-a-half
|
IEEE 1588 and IEC 61850
|
IEEE 1588 and IEC 61850 and Breaker-and-a-half
|
IEEE 1588 and phasor measurement unit (PMU)
|
IEEE 1588 and IEC 61850 and phasor measurement unit (PMU)
|
IEEE 1588 and phasor measurement unit (PMU) and Breaker-and-a-half
|
IEEE 1588 and IEC 61850 and phasor measurement unit (PMU) and Breaker-and-a-half
|
IEEE 1588 and CyberSentry Lvl 1
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
|
IEEE 1588 and CyberSentry Lvl 1 and phasor measurement unit (PMU)
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and phasor measurement unit (PMU)
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 + phasor measurement unit (PMU) + Breaker-and-a-half
2.1 INTRODUCTION
2

2.1.2 ORDERING