GE D60 Instruction Manual page 592

Line distance protection system ur series
Hide thumbs Also See for D60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 4 of 72)
ADDR
REGISTER NAME
1609
Field latching output open driver states
160A
Field latching output close driver states
160B
Field latching output physical states
160C
Field unit online/offline states
160D
Undefined
160E
Undefined
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet primary fibre channel status
1611
Ethernet secondary fibre channel status
1612
Ethernet tertiary fibre channel status
B
Data Logger Actuals (Read Only)
1618
Data logger channel count
1619
Time of oldest available samples
161B
Time of newest available samples
161D
Data logger duration
Sensitive Directional Power Actuals (Read Only) (2 modules)
1680
Sensitive Directional Power 1 Power
1682
Sensitive Directional Power 2 Power
Field Unit RTD Actuals (Read Only) (8 modules)
16C0
Field RTD x Value
16C1
...Repeated for module number 2
16C2
...Repeated for module number 3
16C3
...Repeated for module number 4
16C4
...Repeated for module number 5
16C5
...Repeated for module number 6
16C6
...Repeated for module number 7
16C7
...Repeated for module number 8
Field Unit Transducer Actuals (Read Only) (8 modules)
16C8
Field Transducer x Value
16CA
...Repeated for module number 2
16CC
...Repeated for module number 3
16CE
...Repeated for module number 4
16D0
...Repeated for module number 5
16D2
...Repeated for module number 6
16D4
...Repeated for module number 7
16D6
...Repeated for module number 8
Frequency Rate of Change Actuals (Read Only) (4 modules)
16E0
Frequency Rate of Change 1
16E1
Reserved (3 items)
16E4
...Repeated for Frequency Rate of Change 2
16E8
...Repeated for Frequency Rate of Change 3
16EC
...Repeated for Frequency Rate of Change 4
Source Current (Read Only) (6 modules)
1800
Source 1 Phase A Current RMS
1802
Source 1 Phase B Current RMS
1804
Source 1 Phase C Current RMS
1806
Source 1 Neutral Current RMS
1808
Source 1 Phase A Current Magnitude
180A
Source 1 Phase A Current Angle
180B
Source 1 Phase B Current Magnitude
180D
Source 1 Phase B Current Angle
180E
Source 1 Phase C Current Magnitude
1810
Source 1 Phase C Current Angle
1811
Source 1 Neutral Current Magnitude
B-12
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
-2147483647 to 2147483647
-2147483647 to 2147483647
-32768 to 32767
-32.768 to 32.767
-327.67 to 327.67
0 to 65535
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F134
---
1
F134
---
1
F134
channel
1
F001
seconds
1
F050
seconds
1
F050
days
0.1
F001
W
1
F060
W
1
F060
°C
1
F002
---
0.001
F004
Hz/s
0.01
F002
---
1
F001
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
DEFAULT
0
0
0
0
0
0
0 (Fail)
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GE Multilin