GE D60 Instruction Manual page 618

Line distance protection system ur series
Hide thumbs Also See for D60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 30 of 72)
ADDR
REGISTER NAME
6478
Overfrequency 1 Events
6479
Reserved (4 items)
647D
...Repeated for Overfrequency 2
648A
...Repeated for Overfrequency 3
6497
...Repeated for Overfrequency 4
Power Swing Detect (Read/Write Grouped Setting)
65C0
Power Swing Detect Function
65C1
Power Swing Detect Source
65C2
Power Swing Detect Mode
65C3
Power Swing Detect Supervision
B
65C4
Power Swing Detect Forward Reach
65C5
Power Swing Detect Forward RCA
65C6
Power Swing Detect Reverse Reach
65C7
Power Swing Detect Reverse RCA
65C8
Power Swing Detect Outer Limit Angle
65C9
Power Swing Detect Middle Limit Angle
65CA
Power Swing Detect Inner Limit Angle
65CB
Power Swing Detect Delay 1 Pickup
65CC
Power Swing Detect Delay 1 Reset
65CD
Power Swing Detect Delay 2 Pickup
65CE
Power Swing Detect Delay 3 Pickup
65CF
Power Swing Detect Delay 4 Pickup
65D0
Power Swing Detect Seal In Delay
65D1
Power Swing Detect Trip Mode
65D2
Power Swing Detect Block
65D4
Power Swing Detect Target
65D5
Power Swing Detect Event
65D6
Power Swing Detect Shape
65D7
Power Swing Detect Quad Forward Middle
65D8
Power Swing Detect Quad Forward Outer
65D9
Power Swing Detect Quad Reverse Middle
65DA
Power Swing Detect Quad Reverse Outer
65DB
Power Swing Detect Outer Right Blinder
65DC
Power Swing Detect Outer Left Blinder
65DD
Power Swing Detect Middle Right Blinder
65DE
Power Swing Detect Middle Left Blinder
65DF
Power Swing Detect Inner Right Blinder
65E0
Power Swing Detect Inner Left Blinder
Sensitive Directional Power (Read/Write Grouped Setting) (2 modules)
6680
Sensitive Directional Power 1 Function
6681
Sensitive Directional Power 1 Signal Source
6682
Sensitive Directional Power 1 RCA
6683
Sensitive Directional Power 1 Calibration
6684
Sensitive Directional Power 1 STG1 SMIN
6685
Sensitive Directional Power 1 STG1 Delay
6686
Sensitive Directional Power 1 STG2 SMIN
6687
Sensitive Directional Power 1 STG2 Delay
6688
Sensitive Directional Power 1 Block
668A
Sensitive Directional Power 1 Target
668B
Sensitive Directional Power 1 Events
668C
Reserved (5 items)
6691
...Repeated for Sensitive Directional Power 2
Load Encroachment (Read/Write Grouped Setting)
66C0
Load Encroachment Function
B-38
RANGE
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0.05 to 30
0.1 to 500
40 to 90
0.1 to 500
40 to 90
40 to 140
40 to 140
40 to 140
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 1
0 to 4294967295
0 to 2
0 to 1
0 to 1
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0 to 1
0 to 5
0 to 359
0 to 0.95
-1.2 to 1.2
0 to 600
-1.2 to 1.2
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 65535
0 to 1
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F513
pu
0.001
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
degrees
1
F001
degrees
1
F001
degrees
1
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F514
---
1
F300
---
1
F109
---
1
F102
---
1
F085
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
---
1
F102
---
1
F167
degrees
1
F001
degrees
0.05
F001
pu
0.001
F002
s
0.01
F001
pu
0.001
F002
s
0.01
F001
---
---
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
DEFAULT
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Two Step)
600
5000
75
5000
75
120
90
60
30
50
17
9
17
400
0 (Delayed)
0
0 (Self-reset)
0 (Disabled)
0 (Mho Shape)
6000
7000
6000
7000
10000
10000
10000
10000
10000
10000
0 (Disabled)
0 (SRC 1)
0
0
100
50
100
2000
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
GE Multilin