B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 54 of 72)
ADDR
REGISTER NAME
B224
...Repeated for Received Analog 11
B226
...Repeated for Received Analog 12
B228
...Repeated for Received Analog 13
B22A
...Repeated for Received Analog 14
B22C
...Repeated for Received Analog 15
B22E
...Repeated for Received Analog 16
B230
...Repeated for Received Analog 17
B232
...Repeated for Received Analog 18
B234
...Repeated for Received Analog 19
B236
...Repeated for Received Analog 20
B
B238
...Repeated for Received Analog 21
B23A
...Repeated for Received Analog 22
B23C
...Repeated for Received Analog 23
B23E
...Repeated for Received Analog 24
B240
...Repeated for Received Analog 25
B242
...Repeated for Received Analog 26
B244
...Repeated for Received Analog 27
B246
...Repeated for Received Analog 28
B248
...Repeated for Received Analog 29
B24A
...Repeated for Received Analog 30
B24C
...Repeated for Received Analog 31
B24E
...Repeated for Received Analog 32
IEC 61850 Configurable Report Settings (Read/Write Setting)
B290
IEC 61850 configurable reports dataset items (64 items)
Wattmetric ground fault settings (read/write grouped, 2 modules)
B300
Wattmetric ground fault 1 function
B301
Wattmetric ground fault 1 source
B302
Wattmetric ground fault 1 voltage
B303
Wattmetric ground fault 1 overvoltage pickup
B304
Wattmetric ground fault 1 current
B305
Wattmetric ground fault 1 overcurrent pickup
B306
Wattmetric ground fault 1 overcurrent pickup delay
B307
Wattmetric ground fault 1 power pickup
B308
Wattmetric ground fault 1 ECA
B309
Wattmetric ground fault 1 power pickup delay
B30A
Wattmetric ground fault 1 curve
B30B
Wattmetric ground fault 1 multiplier
B30C
Wattmetric ground fault 1 block
B30E
Wattmetric ground fault 1 target
B30F
Wattmetric ground fault 1 events
B310
Wattmetric ground fault 1 reference power
B311
Wattmetric ground fault x Reserved
B312
...Repeated for wattmetric ground fault 2
B324
...Repeated for wattmetric ground fault 3
B336
...Repeated for wattmetric ground fault 4
B348
...Repeated for wattmetric ground fault 5
Wattmetric ground fault actual values (read only) (5 modules)
B360
Wattmetric ground fault 1 operating power
B362
...Repeated for wattmetric ground fault 2
B364
...Repeated for wattmetric ground fault 3
B366
...Repeated for wattmetric ground fault 4
B368
...Repeated for wattmetric ground fault 5
IEC 61850 XSWI Configuration (Read/Write Setting) (24 modules)
B370
Flexlogic Operand for IEC 61850 XSWI.ST.Loc Status
B-62
RANGE
0 to 848
0 to 1
0 to 5
0 to 1
0.02 to 3.00
0 to 1
0.002 to 30.000
0 to 600
0.001 to 1.2
0 to 360
0 to 600
0 to 5
0.01 to 2
0 to 65535
0 to 2
0 to 1
0.001 to 1.2
0 to 1
0 to 999999.999
0 to 4294967295
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F615
---
1
F102
---
1
F167
---
1
F234
0 (Calculated VN)
pu
0.01
F001
---
1
F235
(Calculated IN)
pu
0.001
F001
s
0.01
F001
pu
0.001
F001
° Lag
1
F001
s
0.01
F001
---
1
F236
0 (Definite Time)
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
pu
0.001
F001
---
1
F001
W
0.001
F060
---
1
F300
DEFAULT
0 (None)
0 (Disabled)
0 (SRC 1)
20
60
20
100
0
20
100
0
0 (Self-reset)
0 (Disabled)
500
0
0
0