Rf Radiation Measurement - CPI S5CIA Installation And Operation Manual

Indoor sspa p/n 01040244r7
Table of Contents

Advertisement

Synthesizer
Table 6-4. Power and Gain Test Data Sheet
Measurements
Gain @ Rated
Small Signal Gain
6.5.2

RF Radiation Measurement

To measure the Indoor SSPA radiation levels:
1. Adjust the Indoor SSPA for rated power.
2. Using a radiation probe, measure the highest level of RF leakage around the amplifier, at less
then 12 inches away from any point source.
3. Record the measured value(s). Measured levels should be less then 1mW/cm². If this value is
exceeded. Shut down the Indoor SSPA and tighten the joints or install grounding or gaskets to
eliminate leakage.
WARNING! IF ANY RF RADIATION LEVELS ARE TO BE MEASURED, CHECK FOR
RF LEAKAGE USING THE STEPS ABOVE.
D
.01040087 R
.6
OC
EV
Power Sensor
& Meter
Indoor
Coupler
Figure 6-1. Performance Test Setup
Low Band
Power Sensor
& Meter
Coupler
SSPA
Frequency
Center Band
M
AINTENANCE
High Power
Load
High Band
6-9