Ip And Cif Setup; Ip Setup; Cif Setup; Activating Computer Control - CPI S5CIA Installation And Operation Manual

Indoor sspa p/n 01040244r7
Table of Contents

Advertisement

9. The reflected power should be less then 10% of the transmitted power. If it is not the quality
of the match to the load (antenna) is poor and should be rectified by shutting the system
down and following the procedures for waveguide installation in the "Unpacking and
Installation" chapter.
10. Perform the power and gain test located in the "Maintenance" chapter.
11. Press the STANDBY key and verify that the main screen has reverted to the standby state
and that no fault message is shown.
12. Switch off all circuit breakers. This concludes the initial power on and checkout procedure.
4.4.5

IP and CIF Setup

Setting up the IP and CIF will enable the operator to control the unit remotely through a local
area network (LAN) or a remote control panel. Remote operation can be performed through a
web browser. Refer to the "Operation" chapter for details.
4.4.5.1

IP Setup

Press the
key to display the menu screen. Cursor over to the
MENU
keys and push
ENTER
simple mail transfer protocol (SMTP) server and the network time protocol (NTP) server
address can be set.
4.4.5.2

CIF Setup

Press the
key to display the menu screen. Cursor over to
MENU
push
. Amp control, amp address, CIF serial type, and CIF protocol can be set to the
ENTER
operators' preference and will enable communication through J7 at the rear of the Indoor SSPA.
4.4.6

Activating Computer Control

The interface parameters of the Indoor SSPA must been set to match those of an external
computer system. Computer control can be activated from either a local control panel or a
remote control panel. Pressing
either LOCAL or REMOTE mode. For more details on communicating locally or remotely refer
to the "External Interfaces" chapter.
D
.01040053 R
.6
OC
EV
. The IP address, mask, and gateway can be set in this submenu. The
key and scrolling over to the
MENU
I
P
O
NITIAL
OWER
N
using the arrow
IP SETUP
using the arrow keys and
SETUP
allows the user to set
SETUP
& C
HECKOUT
4-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S5xiS5cicS5cidS5cibS4uiaS4uib

Table of Contents