Front Panel Led's; Event Log; Fault Log; Histogram Log - CPI S5CIA Installation And Operation Manual

Indoor sspa p/n 01040244r7
Table of Contents

Advertisement

I
NTRODUCTION
1.3.6

Front Panel LED's

Front panel LED's display amplifier status's such as transmit, standby, fault, on-line, and
remote.
1.3.7

Event log

This feature captures events at preset time interval or when there is a change in status. The
entry event log puts a time and date stamp on every entry. After 2000 entries the next entry will
overwrite the oldest one.
1.3.8

Fault Log

The fault log is used to capture in-depth information and can capture 5 separate faults. The
most recent faults are kept in memory, discarding the oldest fault as a new fault occurs.
1.3.9

Histogram Log

The histogram log keeps a record of the amplifier operating conditions over time.
1.3.10

Auto Fault Recycle

If the amplifier fails it will automatically recycle the fault and try to return to its previous state.
This feature allows quick recovery after minor faults.
1.3.11

Internal Test Points

Internal test points have been built into the SSPA allowing for easy measurement and
troubleshooting.
1.3.12
Quick Replacement of Power Supply, Brick,
or Fan
Replacement of the power supply, brick, or fan can be done in less than 1 hour.
1.3.13

RS-232/422/485 Remote CIF Protocol

The SSPA is equipped with a remote CIF protocol that can handle RS-232/422/485.
1.3.14

4 Programmable Discrete Relay Outputs

The D-Type connector J6 at the back of the SSPA has 4 discrete programmable relay outputs.
The outputs can be programmed for any fault or alarm.
1-6
D
.01040043 R
.6
OC
EV

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S5xiS5cicS5cidS5cibS4uiaS4uib