AINTENANCE
Caution: Before attempting any cleaning, remove all power. When using
solvents, provide adequate ventilation and avoid breathing fumes. When
cleaning with air, wear safety goggles and use clean, dry compressed air
not exceeding 25 psi (1.75 kg/cm).
6.3.1

Visual Inspection

At one-month intervals, the Indoor SSPA should be visually inspected for physical defects. If the
equipment is subject to severe environmental conditions, inspections should be performed more
frequently.
The event log is a good source for clues that could indicate an intermittent or marginal condition.
Any increase in reflected power, temperature or unexplained fault conditions could point to a
deteriorating condition.
The circuit breaker must be off while the following general inspection is performed.
Perform the following visual inspection:
Check that all connector plugs are properly seated in their mating connectors and have not
been damaged. Only have a service technician replace any bad connector plugs and reseat any
that are dislodged.
Inspect cables for signs of discolored, broken, or bad insulation. A service technician should
repair or replace cables as needed.
Inspect all waveguide for discoloration, cracks, loose connectors, and improper sealing.
Contact a qualified service technician for repairs.
Check for other defects. These include, but are not limited to, wear, breakage, deterioration,
fungus, excess moisture, and mounting integrity. Contact a qualified service technician for
repairs.
Inspect the air intake filter. This is a removable and washable filter; clean it if necessary.
6.3.2

Unit Cleaning

Look for signs of dirt or moisture contamination, which can cause short-circuiting, arcing,
corrosion, or overheating. Use a lint-free cloth, a small vacuum cleaner, or a compressed-air
blower at low pressure to clean contaminated areas with.
6.3.3

Air Filter Cleaning

Remove the two captive screws in the front panel. Gently pull on the screws and part of the front
panel will detach exposing the reusable filter element. Rinse under warm water and let dry.
Reverse disassembly procedure to reinstall, carefully noting which side of filter faces grill. Indents
in the filter from the grill will indicate which side faces grill.