Teledyne m640 User Manual page 99

Genie nano series monochrome & color gige vision area scan
Hide thumbs Also See for m640:
Table of Contents

Advertisement

Readout Start
Readout End
Frame Trigger
Valid Frame Trigger
Rejected Frame Trigger
MultiFrame End Trigger
Line 1
Line 2
Output 1
Output 2
Timer 1 End
Counter 1 End
Counter Reset Input Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Value
Counter Value At Reset
Counter Reset
Timer Selector
Timer 1
Timer Mode
Off
Active
Timer Status
Timer Idle
Timer Trigger Wait
Timer Active
Timer Completed
Timer Start Source
TimerReset Cmd
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Nano Series GigE Vision Camera
ReadoutStart
ReadoutEnd
FrameStart
ValidFrameTrigger
InvalidFrameTrigger
FrameBurstEnd
Line1
Line2
Line3
Line4
Timer1End
Counter1End
counterResetLineActivation
RisingEdge
FallingEdge
AnyEdge
counterValue
counterValueAtReset
counterReset
timerSelector
Timer1
timerMode
Active
timerStatus
TimerIdle
TimerTriggerWait
TimerActive
TimerCompleted
timerStartSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
Reset the counter on the reception of the Readout
Start event.
Reset the counter on the reception of the Readout
End event.
Reset on reception of the Frame Trigger.
Reset on reception of the Valid Frame Trigger.
Reset on reception of the Invalid Frame Trigger.
Reset on reception of the Frame Burst end.
Reset counter on the specified transition on line 1.
See Input Signals Electrical Specifications.
Reset counter on the specified transition on line 2.
Counts the number of transitions of Output 1 (based
on the counterIncrementalLineActivation feature
setting).
Counts the number of transitions of Output 2 (based
on the counterIncrementalLineActivation feature
setting).
Reset on reception of the Timer End.
Reset on the reception of the Counter end.
Specify the edge transition on the selected line that
will reset the selected counter.
Reset counter on rising edge of the selected signal.
Reset counter on falling edge of the selected signal.
Reset counter on the falling or rising edge of the
selected signal
Read the current value of the selected counter.
Stores the counter value of the selected counter when
it was reset by a trigger or by an explicit Counter
Reset command.
Resets the selected counter to zero. The counter
starts immediately after the reset. To temporarily
disable the counter, set the Counter Event Source
feature to Off.
Selects which timer to configure.
Timer 1 selected
Select the Timer mode. The selected Timer is Active
or Disabled. When Disabled, the Timer can be
configured.
Off
The selected Timer is Disabled.
The selected Timer is Enabled.
Returns the current state of the timer.
The timer is idle. The CounterStartSource feature is
set to off.
The timer is waiting for a start trigger.
The timer is counting for the specified duration.
The timer reached the TimerDuration count.
Select the trigger source to start the timer. The
Control section
provides details and timing diagrams
for the supported events.
Off
Starts with the reception of the TimerReset
Icommand.
Start Timer on Acquisition Start event.
Start Timer on Acquisition End event
Start Timer on Exposure Start event.
Start Timer on Exposure End event.
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Event
Expert
DFNC
Operational Reference • 97