TriggerOverlap=ReadOut
Trigger is accepted at the beginning of the frame Readout. The "End of Exposure to Start of
Readout" time is sensor dependent.
Diagram Conditions:
TriggerMode=On
ExposureMode=Timed
TriggerActivation=RisingEdge
TriggerDelay=0
TriggerSelector=FrameStart
ExposureAlignment=Synchronous
TriggerOverlap=Readout
Trigger Input
Frame Exposure
Frame Readout
Timing specific to OnSemi models
Trigger to Exposure start has a delay which includes the sensor readout time plus a
minimum of 62µs. An exposure always starts after the readout of the previous frame.
Trigger Delay Times (min. with normal ROT):
M/C2590: 23318µs
M/C1930: 10907µs
M/C1280: 5751µs
M/C800: 2407µs
M/C640: 1677µs
Nano Series GigE Vision Camera
Trigger Exclusion Period
Exposure 1
End of Exposure
to Start of Readout
Frame 1 Active period
Trigger Exclusion Period
Exposure 2
End of Exposure
to Start of Readout
Readout 1
Frame 2 Active period
Readout 2