Teledyne m640 User Manual page 97

Genie nano series monochrome & color gige vision area scan
Hide thumbs Also See for m640:
Table of Contents

Advertisement

Display Name
Counter Selector
Counter 1
Counter mode
Off
Active
Counter Status
Counter Idle
Counter Trigger Wait
Counter Active
Counter Completed
Counter Overflow
Counter Start Source
Off
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Valid Frame Trigger
Rejected Frame Trigger
Action 1
Action 2
Line 1
Line 2
Output 1
Output 2
Timer 1 End
Counter 1 End
Nano Series GigE Vision Camera
Feature & Values
counterSelector
Counter1
counterMode
Active
counterStatus
CounterIdle
CounterTriggerWait
CounterActive
CounterCompleted
CounterOverflow
counterStartSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
ValidFrameTrigger
InvalidFrameTrigger
Action1
Action2
Line1
Line2
Line3
Line4
Timer1End
Counter1End
Description
Selects the counter to configure.
Select counter 1
Selects the counter mode. The selected Counter is
either Active or Disabled. When Disabled, the Counter
can be configured.
Off
The selected Counter is Disabled
The selected Counter is Enabled
Returns the current state of the counter.
The counter is idle.
The counterStartSource feature is set to off.
The counter is waiting for a start trigger.
The counter is counting for the specified duration.
The counter reached the CounterDuration count.
The counter reached its maximum possible count.
Select the counter start source. Counter increments
from 0 to the value of the counterDuration feature.
Off
Counter is stopped.
Counter starts on the reception of the Acquisition
Start event.
Counter starts on the reception of the Acquisition End
event.
Counter starts on the reception of the Exposure Start
event
Counter starts on the reception of the Exposure End
event.
Counter starts on the reception of the Readout Start
event.
Counter starts on the reception of the Readout End
event.
Counter starts on the reception of the Frame Start
event.
Counter starts on the reception of the Valid Frame
Trigger.
Counter starts on the reception of the Invalid Frame
Trigger.
GigEVision Action Command 1. This is a broadcast
command that multiple devices can respond to
simultaneously.
GigEVision Action Command 2. This is a broadcast
command that multiple devices can respond to
simultaneously.
Counter starts on the specified transitions on Line 1
See Input Signals Electrical Specifications.
Counter starts on the specified transitions on Line 2
Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of
Output 1.
Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of
Output 2.
Counter starts on the reception of the Timer 1 End
event.
Counter starts on the reception of the Counter 1 End
event.
(1.03)
(1.03)
Operational Reference • 95
Device
Version
& View
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.10
Expert
DFNC