Teledyne m640 User Manual page 98

Genie nano series monochrome & color gige vision area scan
Hide thumbs Also See for m640:
Table of Contents

Advertisement

Counter Start Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Incremental
Source
Off
Acquisition Start
Acquisition End
Exposure Start
ExposureEnd
Readout Start
Readout End
Frame Start
Valid Frame Trigger
Rejected Frame(s)
Trigger
MultiFrame End Trigger
Line 1
Line 2
Output 1
Output 2
Internal Clock
Timer 1 End
Counter Incremental Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Duration
Counter Reset Source
Reset Cmd
Acquisition Start
Acquisition End
Exposure Start
Exposure End
96 • Operational Reference
counterStartLineActivation
RisingEdge
FallingEdge
AnyEdge
counterIncrementalSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
ValidFrameTrigger
InvalidFrameTrigger
FrameBurstEnd
Line1
Line2
Line3
Line4
InternalClock
Timer1End
counterIncrementalLineActivation
RisingEdge
FallingEdge
AnyEdge
counterDuration
counterResetSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
Selects the activation mode of the input line trigger
which starts the counter. This is only applicable when
the counterStartSource feature selects a physical
Line.
Starts counting on rising edge of the selected Line.
Starts counting on falling edge of the selected Line.
Starts counting on the falling or rising edge of the
selected Line.
Select the event source which increments the
counter. The
Event Control section
and timing diagrams for the supported events.
Off
Counter is stopped.
Counts the number of Acquisition Start events.
Counts the number of Acquisition End events.
Counts the number of Exposure Start events.
Counts the number of Exposure End events.
Counts the number of Readout Start events.
Counts the number of Readout End events.
Counts the number of Frame Start events.
Counts the number of Valid Frame Triggers.
Counts the number of Rejected Frame(s) Trigger.
Counts the number of multi-frame end triggers
Counts the number of transitions on Line 1 (based on
the counterIncrementalLineActivation feature setting)
See Input Signals Electrical Specifications.
Counts the number of transitions on Line 2 (based on
the counterIncrementalLineActivation feature setting)
Counts the number of transitions of Output 1 (based
on the counterIncrementalLineActivation feature
setting)
Counts the number of transitions of Output 2 (based
on the counterIncrementalLineActivation feature
setting)
The counter increments on each microsecond tick of
the device internal Clock.
Counts the number of Timer 1 End events.
Selects the counter signal activation mode. The
counter increments on the specified signal edge or
level.
Increment the counter on the rising edge of the
selected I/O Line.
Increment the counter on the falling edge of the
selected I/O Line.
Increment the counter on the falling or rising edge of
the selected I/O Line.
Sets the duration (or number of events) before the
CounterEnd event is generated.
Selects the signal source to reset the counter. After a
reset the counter waits for the next countStartSource
signal or event.
Off
Reset on reception of the Reset Icommand.
Reset on reception of the Acquisition Start.
Reset on reception of the AcquisitionEnd
Reset on reception of the Exposure Start event.
Reset on reception of the Exposure End event.
1.00
Expert
DFNC
1.00
Expert
provides details
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.10
Expert
DFNC
Nano Series GigE Vision Camera