Output Line Source
Software Controlled
Pulse On: Start of Exposure
Exposure Active
Output Line Value
Nano Series GigE Vision Camera
Line 3
Line 4
cP_OutputLineSource
Off
SoftwareControlled
PulseOnStartofExposure
ExposureActive
cP_OutputLineValue
Active
Inactive
Line3
Index of the physical line and associated I/O control block
to use. Pin 6 is the Output Signal and Pin 4 is the
common output power on the I/O connector.
Line4
Index of the physical line and associated I/O control block
to use. Pin 8 is the Output Signal and Pin 4 is the
common output power on the I/O connector.
Selects which internal signal, or event driven pulse, or
software control state to output on the selected output
line.
< Expert, DFNC >
Off
Line output is Open – no output source selected.
The OutputLineValue feature changes the state of the
output.
Generate a pulse on the ExposureStart event. This is
typically used to trigger a strobe light.
Generate a signal that is active when the exposure is
active.
Sets the output state of the selected Line if the
outputLineSoftwareLatchControl = OFF. OutputLineSource
must be SoftwareControlled. If the
outputLineSoftwareLatchControl=Latch, the state of the
pin will change with the outputLineSoftwareCmd
command.
< Expert, DFNC >
Active
Sets the Output circuit to closed.
Inactive
Sets the Output circuit to open.