Teledyne m640 User Manual page 84

Genie nano series monochrome & color gige vision area scan
Hide thumbs Also See for m640:
Table of Contents

Advertisement

Line Format
Opto-Coupled
Line Mode
Input
Output
Line Status
Line Status All
Line Inverter
Input Line Detection Level
Threshold for TTL
Input Line Debouncing
Period
Output Line Source
Off
Software Controlled
Pulse on: Start of Frame
Pulse on: Start of Exposure
Pulse on: End of Exposure
Pulse on: Start of Readout
Pulse on: End of Readout
Pulse on: Valid Frame
Trigger
Pulse on: Rejected Frame(s)
Trigger
Pulse on: Start of Acquisition
Pulse on: End of Acquisition
Pulse on: End of Timer 1
Pulse on: End of Counter 1
Pulse on: Input 1 Event
Pulse on: Input 2 Event
82 • Operational Reference
LineFormat
OptoCoupled
LineMode
Input
Output
LineStatus
False
LineStatusAll
LineInverter
False / True
lineDetectionLevel
Threshold_for_TTL
lineDebouncingPeriod
outputLineSource
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofExposure
PulseOnEndofExposure
PulseOnStartofReadout
PulseOnEndofReadout
PulseOnValidFrameTrigger
PulseOnInvalidFrameTrigger
PulseOnStartofAcquisition
PulseOnEndofAcquisition
PulseOnEndofTimer1
PulseOnEndofCounter1
PulseOnInput1
PulseOnInput2
Specify the current electrical format of the selected
physical input or output. (RO)
The line is opto-Coupled.
Reports if the physical Line is an Input or Output
signal. (RO)
See Input Signals Electrical Specifications.
See Output Signals Electrical Specifications.
The line is an input line.
The line is an output line.
Returns the current status of the selected input or
output line.
The Line is logic LOW
True
The Line is logic HIGH
Returns the current status of all available line
signals, at time of polling, in a single bitfield. The
order is Line1, Line2, Line3, ...
Control to invert the polarity of the selected input
or output line signal.
Specifies the voltage threshold required to
recognize a signal transition on an input line.
A signal below 0.8V will be detected as a Logical
LOW and a signal greater than 2.4V will be
detected as a Logical HIGH on the selected input
line.
Specifies the minimum delay before an input line
voltage transition is recognizing as a signal
transition.
Selects which internal signal or event driven pulse
or software control state to output on the selected
line. Note, the LineMode feature must be set to
Output. The List of supported output line sources is
product-specific. The
Event Control section
provides details and timing diagrams for the
supported trigger modes.
Off
Line output is Open
The OutputLineValue feature changes the state of
the output
Generate a pulse on the start of the Frame Active
event
Generate a pulse on the ExposureStart event. This
option is typically used to trigger a strobe light.
Generate a pulse on the ExposureEnd event. This
option is typically used to trigger a strobe light.
Generate a pulse on the ReadoutStart event.
Generate a pulse on the ReadoutEnd event.
Generate a pulse on the ValidFrameTrigger event.
Generate a pulse on the InvalidFrameTrigger
event.
Generate a pulse when the AcquisiontStart event
occurs.
Generate a pulse when the AcquisiontStop event
occurs.
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the CounterEnd 1 event.
Generate a pulse on the Input signal 1 event
Generate a pulse on the Input signal 2 event
1.00
Expert
1.00
Expert
1.00
Expert
1.00
Expert
1.00
Beginner
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
Nano Series GigE Vision Camera