Diagram Conditions (OnSemi Sensors):
TriggerMode=On
ExposureMode=TriggerWidth
TriggerActivation=RisingEdge
TriggerDelay=0
TriggerSelector=FrameStart
ExposureAlignment=Synchronous
OnSemi Sensor TriggerOverlap= Readout and ExposureMode=TriggerWidth
Trigger Input
Frame Exposure
Frame Readout
Nano Series GigE Vision Camera
Exposure 1
Readout 1
Frame 1 Active period
Exposure 2 delayed so that it ends when Readout 1 ends
Exposure 2
Readout 2
Frame 2 Active period