Designated Enabled
Designated Disabled
Fault Cleared
Fault Detected
State Decision Event
Qualification Timeout
Expires
Announce Receipt Timeout
Expires
Synchronization Fault
Master Clock Selected
Recommended State
Master
Recommended State
Grand Master
Recommended State
Slave
Recommended State
Passive
PTP Transport Protocol
Timestamp Modulo Event
Timestamp Modulo Event
Frequency
Timestamp Modulo Start
Time
Timestamp Modulo Actual
Start Time
Frame Start Data
Frame Start Event ID
Frame Start Event
Timestamp
Exposure Start Event ID
Exposure Start Data
Exposure Start Event
Timestamp
Exposure End Event ID
Exposure End Data
Exposure End Event
Timestamp
Nano Series GigE Vision Camera
DesignatedEnabled
DesignatedDisabled
FaultCleared
FaultDetected
StateDecisionEvent
QualificationTimeoutExpires
AnnounceReceiptTimeoutExpires
SynchronizationFault
MasterClockSelected
RS_Master
RS_GrandMaster
RS_Slave
RS_Passive
ptpTransportProtocol
timestampModulo
timestampModuloFrequency
timestampModuloStartTime
timestampModuloActualStartTime
EventFrameStartData
EventFrameStart
EventFrameStartTimestamp
EventExposureStart
EventExposureStartData
EventExposureStartTimestamp
EventExposureEnd
EventExposureEndData
EventExposureEndTimestamp
Designated Enabled
Designated Disabled
Fault Cleared
Fault Detected
State Decision Event
Qualification Timeout Expires
Announce Receipt Timeout Expires
Synchronization Fault
Master Clock Selected
Recommended State Master
Recommended State Grand Master
Recommended State Slave
Recommended State Passive
Describes the PTP Transport Protocol used.
Specifies the additional interval between the
current timestamp tick and the event generated.
This interval has an 80ns accuracy. Note that the
value zero disables the event generator.
Returns the frequency of the timestamp Modulo
Event (in Hz).
Specifies the timestamp value that must be
exceeded by the incrementing timestamp counter
before the modulo event starts. This Feature is
also used for a "Future" Frame Acquisition.
Displays the actual modulo event start time as
used by the device. When the user specified
"timestampModuloStartTime" is in the future,
timestampModuloActualStartTime=
timestampModuloStartTime. When the user
specified "timestampModuloStartTime" has already
past, the camera automatically recalculates a
future value for "timestampModuloStartTime"
using the user set "timestampModulo" feature
value. This new start time is reported by
"timestampModuloActualStartTime".
Data of the frame start event
Represents the event ID to identify the
EventFrameStart software Event. (RO)
Timestamp of the EventFrameStart event. (RO)
Represents the event ID to identify the
EventExposureStart software Event. (RO)
Data of the exposure start event
Timestamp of the EventExposureStart event. (RO)
Represents the event ID to identify the
EventExposureEnd software Event.
Data of the exposure end event
Timestamp of the EventExposureEnd event. (RO)
1.03
Expert
DFNC
1.03
Expert
DFNC
1.03
Expert
DFNC
1.03
Expert
DFNC
1.03
Expert
DFNC
1.00
Guru
1.00
Guru
1.00
Guru
1.00
Guru
1.00
Guru
1.00
Guru
1.00
Guru
1.00
Guru
1.00
Guru
Operational Reference • 163