Fb29
1st PDOUT map count
Indicates how much PDOUT mapping entries shall be activated in 1st PDOUT1
map.
029Dh
0
Uint8
1
A changed value is stored immediately active and non-volatile.
Fb30
1st PDIN map
Specifies the Pdin mapping. The parameter is set-programmable.
029Eh
see Fb28
Uint32
see Fb28
0
A changed value is immediately stored non-volatile.A changed mapping entry
furthermore causes the switch off of the corresponding mapping and setting of
parameter 1st PDIN map cout = 0. Gaps are not supported by this structure, i.e.
there is no way to declare a mapping inactive.
Fb31
1st PDIN map count
Indicates how much PDOUT mapping entries shall be activated in 1st map.
029Fh
0
Uint8
1
A changed value is stored immediately active and non-volatile.
41