KEB COMBIVERT F5 Instruction Manual page 10

Profinet operator
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Software
The parameter values are only contained in a request with request ID = 2.
Request Reference: 1 ... FFh: Serial number for differentiation of the different requests
Request ID:
Axis-No. = 0, since the F5 PROFINET operator represents an 1:1 gateway.
No. of parameters: 1...39 (max. 39 parameters can be read or written via request)
Attribute:
No. of elements: =1
Parameter number (PNU): Addressing of the parameter (see below)
Format:
The F5 PROFINET operator returns all parameters during reading with format = 4.
Also the master can preset all parameters during writing with format = 4.
No. of values: =1
Parameter response:
Block-Definition
Response header
1st parameter value(s)
:
Nth parameter value(s)
The parameter values are contained in response only at response ID = 1 or 81h or 82h (*3).
(*3)
The change, that a negative write-response (response ID = 82h) also contains parameter values, the
F5-PROFINET software supports beginning with V3.1.
10
Value
01h
02h
Value
10h
20h
30h
Value
1
2
3
4
5
6
7
41h
42h
43h
44h
Byte n
Request reference mirrored
Axis-No. mirrored
Format
Values
Meaning
Request parameter (Read)
Change parameter (Write)
Meaning
Value
Description (not supported here)
Text (not supported here)
Meaning
Boolean
Integer8
Integer16
Integer32
Unsigned8
Unsigned16
Unsigned32
Word
DWord
Error
Byte n+1
Response ID
No. of parameters = n
No. of values
:
Byte
n
0
2
4 + 6 x n
: