Sigma II User's Manual
5.5.4

Speed Coincidence Output (/V-CMP)

The basic use and wiring procedures for the speed coincidence (/V-CMP) output
signal (photocoupler output signal), used to indicate a match with the speed
reference, are described below. The host controller uses the signal as an interlock.
Photocoupler output levels per output node:
• Maximum operating voltage: 30V
• Maximum output current: 50mA
Output
/V-CMP CN1-25
This signal is output when the actual motor speed during speed control is the same as
the speed reference input.
/V-CMP
State
ON
OFF
The following parameter setting is used to change the CN1 connector terminal that
outputs the /V-CMP signal.
Parameter
Pn50E
Output Signal Selections 1
The parameter is default set so the /V-CMP signal is output between CN1-25 and 26.
See 5.3.4 Output Circuit Signal Allocation for more details on parameter Pn50E.
DC
DC
Speed Coincidence Output
Signal
Status
Circuit between CN1-25 and 26 is
closed, and CN1-25 is at low level.
Circuit between CN1-25 and 26 is
open, and CN1-25 is at high level.
Motor
speed
/V-CMP is output in this range.
Signal
Chapter 5: Parameter Settings and Functions
Servo amplifier
CN1-25 /V-CMP+
CN1-26 /V-CMP-
Speed coincides. (Speed error is below
the setting).
Speed does not coincide. (Speed error
is above the setting).
Pn503
Reference speed
Setting
(rpm)
Default Setting: 3211
5-75
I/O power supply
0V
+24V
Speed Control
Result
Description
Position Control