Three-Phase (200V) Main Circuit Specifications - YASKAWA SGMAH User Manual

Sigma ii series servo system
Hide thumbs Also See for SGMAH:
Table of Contents

Advertisement

Sigma II User's Manual
3.1.2

Three-Phase (200V) Main Circuit Specifications

Molded-Case Circuit
Breaker (MCCB)
Protects the power
line by shutting
OFF the circuit
when overcurrent
is detected.
Noise Filter
Used to eliminate external
noise from the power line.
Magnetic Contactor
HI Series
Turns the servo
ON and OFF.
Install a surge
suppressor on
the magnetic
contactor.
Brake Power Supply
Used for a servomotor
with a brake.
Regenerative Resistor
Connect an external regenerative
resistor to terminals B1 and B2 if
the regenerative capacity is
insufficient.
For 6kW or higher, an external
resistor is required.
Power supply
Three-phase 200V
AC
R S T
MCCB
Noise filter
Magnetic
contactor
Power
supply
ground
line
Brake
power
supply
Magnetic
contactor
3 - 5
Connect the SGDH servo amplifier
Host
to a Yaskawa host controller or to
Controller
one made by another company.
MEMOCON GL120, GL130
with a motion module.
Digital Operator
Personal Computer
Cable model: YS-12
Regenerative
resistor
(optional)
Chapter 3: Wiring
JUSP-OPO2A-1
and JZSP-CMS00-1
(cable)
Allows the user to
set parameters or
operation references
and to display opera-
tion or alarm status.
Communication
and control is also
possible with a
personal computer.
Encoder
Cable
Encoder
Connector

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmbhSgmphSgmghSgmshSgmuh

Table of Contents