YASKAWA SGMAH User Manual page 316

Sigma ii series servo system
Hide thumbs Also See for SGMAH:
Table of Contents

Advertisement

Sigma II User's Manual
This completes the manual zero adjustment of the analog monitor output.
Using the Built-in Panel Operator
YASKAWA
200V
SERVOPACK
SGDM-
1. Press the MODE/SET key to select the auxiliary function mode.
MODE/SET
DATA/
CHARGE
POWER
2. Press the Up Arrow
3. Press the DATA/SHIFT key for a minimum of one second, and the display will
be as shown below.
4. Press the MODE/SET key. Each time the MODE/SET key is pressed, the
monitor output will toggle between the displays for the two channels shown
below.
5. Press the DATA/SHIFT key for less than one second, and the analog monitor
gain parameter will be displayed. Pressing the DATA/SHIFT key again for less
than one second will return to the display shown in the above steps 3 or 4.
6. Press the Up Arrow
analog monitor output.
7. When zero adjustment has been completed for the two channels, press the
DATA/SHIFT key for a minimum of one second to return to the auxiliary
function mode display.
This completes the manual zero adjustment of the analog monitor output.
or Down Arrow
key to select the parameter Fn00C.
MODE/SET Key
Displayed
Alternately
Data Display
DATA/SHIFT Key
Displayed
Alternately
or Down Arrow
key to perform zero adjustment of the
Data Setting Change
7 - 46
Chapter 7: Using the Digital Operator

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmbhSgmphSgmghSgmshSgmuh

Table of Contents