4. Swing Control
Provides 360 degrees continuous turntable rotation.
5. Lift Control
Provides raising and lowering of the main boom.
NOTE: With PLATFORM/GROUND SELECT switch in the center
position, power is shut off to controls at both operating
stations.
6. Platform/Ground Select Switch
A three position, key operated switch supplies power to
the platform control console when positioned to PLAT-
FORM. With the switch key held in the GROUND posi-
tion, power is shut off to platform and only ground
controls are operable.
7. Hourmeter
Registers the amount of time the machine has been in
use, with engine running. By connecting into the oil
pressure circuit of the engine, only engine run hours are
recorded. The hourmeter registers up to 9,999.9 hours
and cannot be reset.
3121141
SECTION 3 - MACHINE CONTROLS AND INDICATORS
NOTE: When Power/Emergency Stop switch is in the "ON" posi-
tion and engine is not running, an alarm will sound, indi-
cating Ignition is "ON".
WHEN THE MACHINE IS SHUT DOWN THE MASTER/EMERGENCY STOP
SWITCH MUST BE POSITIONED TO THE "OFF" POSITION TO PREVENT
DRAINING THE BATTERY.
8. Power/Emergency Stop Switch
A two-position red mushroom shaped switch furnishes
power to PLATFORM/GROUND SELECT switch when
pulled out (on). When pushed in (off), power is shut off
to the PLATFORM/GROUND SELECT switch.