SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
C: Wheel Drive Hub - Reggiana Riduttori (S/N 134389 to
Present)
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200
hours of operation
Comments - Place Fill port at 12 o'clock position and
Check port at 3 o'clock position. Pour lubricant into fill
port until it just starts to flow out of check port.
6-18
5. Hydraulic Return Filter
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator
6. Hydraulic Charge Filter
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator.
– JLG Lift –
3121141

Hide quick links: