Appendix A: Specifications and Reference Data
April 2013
Table 15. Rosemount 2051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
(4)
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
(4)
K2
INMETRO Flameproof and Intrinsic Safety
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
(4)
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7)
(4)
KA
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5,
and I6)
(4)
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
(4)
KD
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1)
(4)
N1
ATEX Type n
(4)
N7
IECEx Type n
(4)
ND
ATEX Dust
Sensor Fill Fluid and O-ring Options
Standard
L1
Inert Sensor Fill Fluid
L2
Graphite-Filled (PTFE) O-ring
LA
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
Display and Interface Options
Standard
(6)
M4
LCD Display with Local Operator Interface
M5
LCD Display
Transient Protection
Standard
(9)
T1
Transient terminal block
Manifold for Remote Mount Option
Standard
F2
3-Valve Manifold, Stainless Steel
F6
5-Valve Manifold, Stainless Steel
Alarm Limit
Standard
(10)(11)
C4
NAMUR Alarm and Saturation Levels, High Alarm
(10)(11)
CN
NAMUR Alarm and Saturation Levels, Low Alarm
(10)
CR
Custom Alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
(10)
CS
Custom Alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
(10)
CT
Low Alarm (standard Rosemount alarm and saturation levels)
PlantWeb Control Functionality
Standard
(8)
A01
F
fieldbus Advanced Control Function Block Suite
OUNDATION
Hardware Adjustments
Standard
(10)
D4
Zero and Span Hardware Adjustments
(10)
DZ
Digital Zero Trim
Ground Screw
Standard
(12)
V5
External Ground Screw Assembly
HART Revision Configuration
Standard
(10)
(13)
HR5
Configured for HART Revision 5
(10)
(14)
HR7
Configured for HART Revision 7
Typical Model Number: 2051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5