Appendix A: Specifications and Reference Data
April 2013
Table 13. Rosemount 2051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Material Traceability Certification
Standard
Q8
Material Traceability Certification per EN 10204 3.1.B
Quality Certification for Safety
Standard
(12)
QS
Prior-use certificate of FMEDA data
(12)
QT
Safety Certified to IEC 61508 with certificate of FMEDA
Surface Finish
Standard
Q16
Surface finish certification for sanitary remote seals
Toolkit Total System Performance Reports
Standard
QZ
Remote Seal System Performance Calculation Report
Conduit Electrical Connector
Standard
GE
M12, 4-pin, Male Connector (eurofast
GM
A size Mini, 4-pin, Male Connector (minifast
HART Revision Configuration
Standard
(7)
(15)
HR5
Configured for HART Revision 5
(7)
(16)
HR7
Configured for HART Revision 7
Typical Model
Number:
(1)HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART
Revision 7. To order HART Revision 7 factory configured, add option code HR7.
(2)Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for
sour refining environments.
(3)Not available with Low Power output code M.
(4)"Assemble-to" items are specified separately and require a completed model number.
(5)Not available with coned and threaded connection (2F code), assemble-to manifold (S5 code), assemble-to seal (S1 code), surface finish
certification (Q16 code), remote seal system report (QZ code).
(6)Not available with FOUNDATION fieldbus output code F.
(7)Only Available with HART 4-20 mA (output codes A and M).
(8)Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(9)The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(10)Available with 4-20 mA HART output code A, FOUNDATION fieldbus output code F, 2051C Ranges 2-5 or 2051T Ranges 1-4, SST
diaphragms and silicone fill fluid. High Performance Option includes 0.05% Reference Accuracy, 5 year stability and improved ambient
temperature effect specifications. See Performance Specifications for details.
(11)The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes
IA and IE.
(12)Only available with HART 4-20 mA output (output code A).
(13)NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(14)Not valid with Alternate Process Connection S5.
(15)Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(16)Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
136
®
)
®
2051T G 3 A 2B 2 1 A B4 M5
)
Reference Manual
00809-0100-4107, Rev BA
Appendix A: Specifications and Reference Data