CHAPTER 7. Connecting Stations and Additional Equipment
Connect the 4WLI module and WBS24 using two 0.64 mm twisted cables (RJ-45 Ethernet
cable, 600 m maximum distance) or two 0.40 mm twisted cables (RJ-45 Ethernet cable,
400 m maximum distance).
Wiring between 4WLI and WBS24
WBS24 Port Pin No.
4
5
3
6
4
5
3
6
4
5
3
6
4
5
3
6
Use twisted pair cable.
7-8
Installation and Usage of WBS24 and WIP-5000M
For information on how to install and use the WBS24 and WIP-5000M, refer to
the appropriate documentation provided with these.
Figure 7.14 RJ-45 4WLI Module Port
Table 7.3 Wiring between 4WLI and WBS24
WBS24 No.
1
2
3
4
P1-P4 Ports
(RJ-45)
Signal
D Channel Data
Sync. Line
D Channel Data
Sync. Line
D Channel Data
Sync. Line
D Channel Data
Sync. Line
© Samsung Business Communications.
4WLI Port Pin No.
4
5
3
6
4
5
3
6
4
5
3
6
4
5
3
6