This chapter describes how to connect C.O. lines to the OfficeServ 7400 system.

6.1 Line Conditions

Precaution to take when connecting C.O. lines are as follows:
Use cables with AWG #24 or AWG #26 width for subscriber lines.
When wiring cables in high-humidity areas, put in place remedies for removing mois-
ture before wiring.
Cables should be handled carefully to prevent any damage.
Subscriber lines should be kept routed indoors if possible.
Do not route subscriber lines around high-voltage power lines.
The leak resistance of C.O. lines connected to the OfficeServ 7400 system are shown in
Table 6.1.
Leak Resistance between Lines
Leak Resistance between Grounds
© Samsung Business Communications

Connecting C.O. Lines

Table 6.1 Leak Resistance of OfficeServ 7400 Lines

Line Condition
OfficeServ 7400 Installation Guide
Leak Resistance
20 kΩ or higher
20 kΩ or higher