Process Conditions; Probe Specifications - Magnetrol eclipse Enhanced Model 705 Installation And Operating Manual

Guided wave radar level transmitter
Hide thumbs Also See for eclipse Enhanced Model 705:
Table of Contents

Advertisement

7.3 Process Conditions

Model
Maximum
Process Temperature
Maximum
Process Pressure
Maximum Viscosity
Dielectric Range
Hermeticity

7.4 Probe Specifications

Single Rod Probes
Model
Wetted Metallic Parts
Elastomer and Polymeric
Wetted Parts
Diameter
Blocking Distance – Top
Process Connection
Transition Zone (Top)
Transition Zone (Bottom)
Pull Force/Tension
Side Load
Temperature/Pressure Charts
200
100
0
50
100
Process Temperature ( ° F) (max. 300)
57-642 ECLIPSE Model 705 Guided Wave Radar Transmitter for Hygienic Industries
Hygienic
(7xF-E or 7xH-x)
+300° F @ 200 psig
(+150° C @ 13.7 bar)
200 psig @ +300 °F
(13.7 bar @ 150 °C
10,000
(consult factory if severe agitation/turbulence)
≥1.9
N/A
7xF–E
316L SS, <15 R a max. electropolished finish
(Optional: Hastelloy C, AL6XN SS)
TFE (GRAS 21CFR177-1550 and USP <88>
Class VI at 121° C)
0.5" (13 mm)
0.25" (7 mm) for
3
" tri-clamp
4
0–36" (0–91 cm)–Probe length dependent (adjustable)
3
" – 4" Tri-clamp
4
flange
Application Dependent
ε
1" (2.5 cm) @
N/A
Not more than 3" deflection at
end of 72" (183 cm) probe
200
300
7XF/7XH
316L SS, <15 R a max. electropolished finish
PEEK and O-ring (Viton or EPDM) (GRAS 21CFR177
0–36" (0–91 cm)–Probe length dependent (adjustable)
r >10
13.8
6.9
0
10
38
Process Temperature ( ° C) (max. 150)
7xH–x
(Optional: Hastelloy C, AL6XN SS)
and USP <88> Class VI at 121°C
0.5" (13 mm)
3
" – 4" Tri-clamp
4
flange
Application Dependent
ε
1" (2.5 cm) @
r >10
N/A
Not more than 3" deflection at
end of 72" (183 cm) probe
93
150
7XF/7XH
43

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the eclipse Enhanced Model 705 and is the answer not in the manual?

This manual is also suitable for:

Eclipse 705

Table of Contents